Home > Products > Transfected Stable Cell Lines > Reporter Stable Cell Lines >

SK-BR-3 Luciferase Reporter Cell Line

18

Product Name

SK-BR-3 Luciferase Reporter Cell Line

Price Get Quote
Product Code

SK-BR-3 Luciferase Cell Line

Cat.No

ABC-RC351H

Species

Human

Cell Type

Epithelial

Growth Mode

Adherent

Size/Quantity

1 vial

Biosafety Level

1

Shipping Info

Dry Ice

Storage

Liquid Nitrogen

Description

The SK-BR-3 Luciferase Reporter Cell Line is a stable, clonal cell line derived from SK-BR-3 breast cancer cells, engineered to express the firefly luciferase gene. This cell line constitutively expresses luciferase, making it ideal for cell-based assays that require consistent and reliable signal detection. SK-BR-3 cells, originally isolated from a 43-year-old female adenocarcinoma patient, are known for overexpressing the HER2/c-erb-2 gene product. These cells are widely used in cancer research, particularly for studying HER2-positive breast cancer, and their luciferase expression allows for easy monitoring in experimental settings.

 

Why choose SK-BR-3 Luciferase Reporter Cell Line from AcceGen?

SK-BR-3 Luciferase Reporter Cell Line from AcceGen has reliable quality. AcceGen ensures rigorous quality control, including mycoplasma-free certification and STR identification, providing consistent and authentic cells. With expertise in cell culture, this line is ideal for HER2-positive breast cancer research and drug testing.

Disease

Adenocarcinoma

Source Organ

Breast; Mammary Gland

Quality Control

All cells test negative for mycoplasma, bacteria, yeast, and fungi.

Recommended Medium And Supplement
Citation Guide

When you publish your research, please cite our product as “AcceGen Biotech Cat.# XXX-0000”. In return, we’ll give you a $100 coupon. Simply click here and submit your paper’s PubMed ID (PMID).

Host Cell

SK-BR-3 Cell Line

Application

FOR RESEARCH USE ONLY

The SK-BR-3 Luciferase Reporter Cell Line is a powerful tool for HER2-positive breast cancer research, particularly in exploring drug resistance mechanisms. Researchers can use these cells to investigate molecular pathways, providing critical insights into therapeutic targets and strategies to overcome resistance in this aggressive cancer subtype. Additionally, the luciferase expression allows for real-time monitoring of cell viability and drug efficacy. With its tumorigenic properties, the SK-BR-3 line is also useful for establishing adenocarcinoma models in nude mice, facilitating preclinical drug testing and the evaluation of antiproliferative activity of potential therapies.

Growth Conditions

37 ℃, 5% CO2

Stock

In Stock

Product Type

Reporter Stable Cell Line

Product Image AcceGen Frozen Cells & Cell Lines 1 vial

Frequently Asked Questions

  • What is the purpose of using SK-BR-3 Luciferase Reporter Cell Line?

    The SK-BR-3 Luciferase Reporter Cell Line is used for studying eukaryotic gene expression and cell physiology. The luciferase gene system is applied due to its high sensitivity and success rate, enabling various applications such as promoter activity research, mammalian cell two-hybrid experiments, and in vivo imaging experiments.

  • How is luciferase activity validated?

    Luciferase activity is validated using the Dual-Luciferase® Reporter Assay System Kit. The firefly luciferase reaction intensity is measured using a microplate reader, ensuring accurate detection of luciferase activity.

  • What is the recommended procedure to thaw SK-BR-3-Luc cells?

    To thaw SK-BR-3-Luc cells:
    Warm the complete culture medium to 37°C.
    Transfer the cryopreserved vial from liquid nitrogen to a -80°C freezer briefly, then thaw it in a 37°C water bath.
    After thawing, centrifuge the cells, discard the supernatant, and resuspend them in fresh medium before incubating them in a T25 flask in a 37°C, 5% CO₂ incubator.

  • What are the shipping and storage conditions for the SK-BR-3 Luciferase Reporter Cell Line?

    The cells are shipped on dry ice. Upon receipt, they should be transferred immediately to a liquid nitrogen tank (-180°C) for long-term storage. The cells should not be stored at -20°C as this will not preserve them properly.

  • What quality control measures are implemented for the SK-BR-3-Luc Cell Line?

    Each vial of the SK-BR-3-Luc cell line contains over 1×10⁶ cells with more than 90% viability. The cells are tested negative for HIV-1, HBV, HCV, mycoplasma, bacteria, yeast, and fungi.

  • ONLINE INQUIRY
  • PRODUCT REVIEWS
We know how valuable your research is to you, but are you wondering what you can expect to pay for quick accurate results every time?

Fill out a request in the form below and we’ll get back to you within 24 hours with a quote.
Privacy Policy: AcceGen will never sell, rent, or share your personal information with any third parties without your express permission.
Reviews of SK-BR-3 Luciferase Reporter Cell Line
AcceGen is always trying to do right by our customers and working hard to build a higher quality product.

Your email address will not be published.

AcceGen Scroll Top Button